![]() ![]() Now under Host and Port, enter adam's IP and the port 10001 separated with a colon. In the screen “Connections to Meters”, click “New Connection” and enter the name “adam tcp bridge” and click OK. Under connection type, select “Network Flag”. Still in the “What to read” screen, click the big red arrow at the top “Quick Send”. Next we are going to create a connection type that connects to adam (or your server, if you are not using adam). After selecting everything that you want to read, click the “Save Scheme” button at the top. Specifically: “Meter Identifiers” on the right has the multidrop address. Reading “All Data” takes a long time (more than 10 minutes over gprs) so you might want to only read a couple of days. The “What to read” screen should come up and here we can choose from a wide variety of things to read. In the dropdown select New → A1140 Data To Read Provide a name for the scheme e.g. In the scheme manager, right click in the big open space on the right. Next we are going to create a scheme to read the meter. If you are unsure, just restart the entire application. Changes will not apply until it is restarted. After changing the communications server setup, you need to close the communications server, if it was open. Change the Flag turn around time to 500 and and the flag inter-message timeout to 22000. If you are hosting on our central server, use. Under port configuration on the right, enter your server's host name. Double click COM24 in the table and a dropdown will pop up. Go to System → Communications Server Setup Select the Port Setup tab In the table on the left, select a port that is not used by your computer, e.g. First, we are going to setup the Communications Server. The default username is Elster and the default passowrd is Elster. We are going to setup a scheme to read the Profile, Multidrop Address and CT ratio. Communications Server The communications server is used to send a scheme to a meter. And Communications Server Scheme Master The Scheme Master is used to create schemes to read or program the meter. ![]() You can get PMU from Elster, or download it at And version 3 at PMU consists of 2 programs. Remember that PMU for AS230 is version 3 of the PMU. It should be possible to use for an A1700 or AS230. NOTE: this mostly works for SMARTset too, except for creating a new connection which is described in the second post below. This document describes how to read an Elster A1140 over TCP to get the Multidrop address (or Outstation number or bus id) with Elster's Power Master Unit Software (PMU). ![]()
0 Comments
Leave a Reply. |
AuthorWrite something about yourself. No need to be fancy, just an overview. ArchivesCategories |